Induron Coatings Around the World: A Proven Solution for an Aging International Grid

October 17, 2022Coatings, Induron, T&D industryBirmingham, coatings, induron, Induron coatings, Induron Protective Coatings, T&D, transmission & distributioninduron

By: Ben Rowland, T&D Sales at Induron

International T&D BusinessAs a follow up to a previous blog concerning the aging electrical infrastructure of the U.S., and recent regulatory changes that provide a more proactive pathway to successfully extend the life cycle of this infrastructure, I wanted to draw attention to the same need for a solution abroad.  Continue reading Induron Coatings Around the World: A Proven Solution for an Aging International Grid →

Leave a comment

Categories

  • Coatings
  • Holidays and Events
  • Induron
  • Induron Family
  • Induron In the News
  • Induron Values
  • Infrastructure
  • Project Spotlight
  • Safety
  • T&D industry
  • Uncategorized
  • Wastewater Industry
  • Water

Archives

  • September 2023
  • August 2023
  • July 2023
  • June 2023
  • May 2023
  • April 2023
  • March 2023
  • February 2023
  • January 2023
  • December 2022
  • November 2022
  • October 2022
  • September 2022
  • August 2022
  • July 2022
  • June 2022
  • May 2022
  • April 2022
  • March 2022
  • February 2022
  • January 2022
  • December 2021
  • November 2021
  • October 2021
  • September 2021
  • August 2021
  • July 2021
  • June 2021
  • May 2021
  • April 2021
  • March 2021
  • February 2021
  • January 2021
  • December 2020
  • November 2020
  • October 2020
  • September 2020
  • August 2020
  • July 2020
  • June 2020
  • May 2020
  • April 2020
  • March 2020
  • February 2020
  • January 2020
  • December 2019
  • November 2019
  • October 2019
  • September 2019
  • August 2019
  • July 2019
  • June 2019
  • May 2019
  • April 2019
  • March 2019
  • February 2019
  • January 2019
  • December 2018
  • November 2018
  • October 2018
  • September 2018
  • August 2018
  • July 2018
  • June 2018
  • May 2018
  • April 2018
  • March 2018
  • February 2018
  • January 2018
  • December 2017
  • November 2017
  • October 2017
  • September 2017
  • August 2017
  • July 2017
  • June 2017
  • May 2017
  • April 2017
  • March 2017
  • February 2017
  • January 2017
  • December 2016
  • November 2016
  • October 2016
  • September 2016
  • August 2016
  • July 2016
  • June 2016
  • May 2016
  • April 2016
  • March 2016
  • February 2016
  • January 2016
  • December 2015
  • November 2015
  • October 2015
  • September 2015
  • August 2015
  • July 2015
  • June 2015
  • May 2015
  • April 2015
  • March 2015
  • February 2015
  • January 2015
  • December 2014
  • November 2014
  • October 2014
  • September 2014
  • August 2014
  • July 2014
  • June 2014
  • May 2014
  • April 2014
  • March 2014
  • February 2014
  • January 2014
  • December 2013
  • November 2013
  • October 2013
  • September 2013
  • August 2013
  • July 2013
  • June 2013
  • May 2013
  • April 2013
  • March 2013
  • February 2013
  • January 2013
  • December 2012
  • November 2012
  • October 2012
  • September 2012
  • August 2012
  • July 2012
  • June 2012
  • May 2012
  • April 2012
  • March 2012
  • February 2012
  • January 2012
  • December 2011
  • November 2011
  • October 2011
  • September 2011
  • August 2011
  • July 2011
  • June 2011
  • May 2011
  • April 2011
  • March 2011
  • February 2011
  • January 2011

Recent Posts

  • Discovering Global Markets
  • Questioning our Assumptions about Primers in Immersion and their Place in the Water Industry: A Brief, Plain English Summary
  • What is going on in the T&D Market?
  • A New Look for TL-70
  • Project Spotlight: Brighton, MI Tank Rehab
 
Induron Protective Coatings. All rights reserved.     800-324-9584    




  • Water Tank
  • Industrial
  • Treatment Plant
  • Power
  • Pipe Products
  • All Products

WHAT was PUC told to get this approved?

This is a NEW ADDITION providing SIGNIFICANT IMPACT on the tower to ENHANCE SERVICE LIFE.

While fixing foundations maintains what’s already there, applying Induraguard 9200 is like adding a fresh layer. It’s a new addition. The process needs to be done on a larger scale, so it’s important enough to be closely looked at by the Public Utilities Commission (PUC). With the huge U.S. electrical grid that can rust over time, the importance is clear. When this helps a structure stay useful for much longer and costs much less than getting a new one, it’s a real benefit for ratepayers.

WHY are you hearing this now?

The recent FERC ruling outlined the specific requirements for obtaining CapEx treatment when revitalizing towers.

FERC (Federal Energy Regulatory Commission) Update Enables Capitalization of T&D Coatings Initiatives
Formerly, utility companies could include replacement costs for transmission towers and poles in their capitalization, but corrosion control for these assets was excluded. A groundbreaking shift introduced by the Federal Energy Regulatory Commission now allows utility providers to categorize corrosion control programs (coating programs) for transmission structures as a “significant addition,” thereby enabling them to capitalize these expenses for accounting purposes. This alteration is poised to significantly impact the condition of the nation’s aging electric utility infrastructure.

On February 22, 2022, the Federal Energy Regulatory Commission (FERC) approved a utility company’s proposal to classify their tower coating programs as “substantial additions.” The order (1) clarifies, “The Commission has previously permitted utilities to consider the addition of minor property items that were previously absent as substantial additions and to capitalize the related costs when such costs extend the useful life, operational capacity, or efficiency of the associated retirement units.” Utility companies are now authorized to capitalize on the costs linked with corrosion control. This change aligns with generally accepted accounting principles (GAAP) and offers various financial advantages, including a more balanced assets-to-liabilities ratio and reduced income fluctuations.

In numerous instances, corrosion control solutions such as coatings have been repeatedly applied to structures, demonstrating anticipated performance and proven outcomes. Corrosion control coating programs, such as Induraguard 9200, possess the capacity to effectively prolong the service life of structures indefinitely.

HOW is this possible?

PG&E successfully presented a rate case supporting their proposal, citing examples of Southern Company and other utilities employing similar CapEx treatment. The PUC specified certain documentation requirements, but in the end, they granted the CapEx treatment as long as those requirements were met.

“Why should the ratepayer or the environment be asked to bear the cost of a new tower when coatings can be used to keep the one we already have operating indefinitely at a much lower cost?”

In PG&E’s success rate case proposal, FERC highlighted that comparable accommodations have been extended to prominent utilities such as Georgia Power and Southern California Edison. This ruling established a much-needed precedent and framework for other utilities to make the case that they have a responsible coatings program. Such programs can significantly enhance existing structures and potentially extend their operational lifespan by two decades or beyond.

The Tower Is Revitalized

Once the integrity of the galvanizing is compromised, the tower’s initial environmental protection is ineffective. However, the structural integrity remains intact. Implementing a new protective measure will ensure its preservation.

The application of Induraguard 9200 involves installing it on energized towers, typically at a rate of 1-2 towers per day for standard sizes.

Results In Monetary and Environmental Savings

Using Induraguard 9200 to restore a tower costs much less than replacing the whole tower – less than a tenth of the cost. It achieves the same goal while significantly reducing the need for procurement, engineering, and other human resources.

The environmental impact of mining, fabricating, shipping, and installing a new tower is drastically more detrimental compared to the environmental impact of prolonging the use of existing infrastructure.

Achieves An Indefinite Service Life

These structures, composed of steel and reinforced concrete, possess an indefinite design life if we manage environmental deterioration. This means there is no predetermined limit on the amount of value and serviceability after the initial installation at the ratepayer’s expense.

By implementing future applications of Induraguard 9200, the potential utilization timeframe for the structure becomes limitless. This becomes especially significant due to the existing strain on constructing new power infrastructure. It underscores the fact that we cannot simultaneously construct all the required new facilities and overhaul the current grid.

Revitalization Is Now A Capital Expense

The utilization of Induron’s Induraguard 9200 as a protective coating has gained recognition as a Capital Expense by both FERC and Public Utilities Commissions across the United States. This acknowledgment enables the potential cost of installing a replacement tower to come off of ratepayers while permitting the utilization of CapEx funds for this undertaking.

The Replacement Tower Is Now A Capital Expense

Once the existing tower has reached the end of its serviceable lifespan, the cycle starts over — thorough planning, procurement efforts, and assessment for a rate case to install a new replacement tower that is incredibly expensive and potentially disruptive to critical power transmission. This will be classified as a Capital Expense, thereby falling within the responsibility of the ratepayers again.

The Tower Corrodes And Needs Replacement

As the galvanizing layer diminishes, corrosion sets in, initiating the deterioration of the asset itself. This progression leads to visible corrosion and a reduction in structural integrity, ultimately necessitating the replacement of the entire structure.

Maintenance is classified as an O&M expense

Maintenance activities for the tower are categorized under Operations & Maintenance expenditures. Given that the asset was acquired using CapEx funds from ratepayers, the mentality of operation-to-failure takes hold. The objective then shifts to maximizing the asset’s operational lifespan before allocating further CapEx funds for its replacement.

The Tower Needs Maintenance

Over the tower’s lifespan, regular maintenance tasks are performed. Bolts are periodically replaced, foundations undergo repairs, and in some instances, structural elements are swapped out. However, it’s important to note that these routine maintenance activities do not mitigate the gradual degradation of the galvanizing layer, which ultimately leads to corrosion and, ultimately, the failure of the entire structure over time.

The Tower Is Built

The need for a new power transmission line is assessed, followed by meticulous planning, procurement of materials, and installation. The newly constructed tower is fortified with a protective layer of zinc, commonly referred to as galvanizing, which can have a lifespan of 20 to 50 years, contingent upon its quality, quantity, and service environment. This is financed through Capital Expenditure (Capex) funding, thereby distributing the financial responsibility to ratepayers through their imposed rates.